severity.alarms
Alarms severity
type |
object |
||
properties |
|||
|
Flag to indicate that this severity is the default severity in case of empty filters.If true this severity is the default “empty clear severity” for alarm filters (must be set on at most one severity). Default value is [false] |
||
type |
boolean |
||
default |
False |
||
|
The expiration policy of the severity. If none is provided alarms with this severity will never expire. |
||
oneOf |
|||
|
Name of the playbook that generated this file. If present, the file is managed by the Composer and may be overwritten on regeneration. Used for selective clean. Do not edit or set manually. |
||
type |
string |
||
|
The id of the alarm module to attach this severity to |
||
type |
string |
||
|
The id of the template to use for this file |
||
type |
string |
||
|
The variables and their values to be replaced from the template |
||
type |
object |
||
additionalProperties |
|||
|
The variables files to use to replace the variables. The first file of the list will take precedence over the following one. Template variables take precedence over the contents of the files. |
||
type |
array |
||
items |
type |
string |
|
additionalProperties |
False |
||
REMOVE
type |
object |
|
properties |
||
|
type |
string |
enum |
REMOVE |
|
default |
REMOVE |
|
|
The period of time after which alarms with this expire. This duration must be expressed as _value_ and _unit_. |
|
|
The state of the alarm can be used to limit the expiration. ACKNOWLEDGED to only check on acknowledged alarm, UNACKNOWLEDGED or ALL. |
|
type |
string |
|
enum |
ALL, ACKNOWLEDGED, UNACKNOWLEDGED |
|
additionalProperties |
False |
|
DurationConfigurationEntity
type |
object |
|
properties |
||
|
The unit of time expressed |
|
type |
string |
|
enum |
NANOSECONDS, MICROSECONDS, MILLISECONDS, SECONDS, MINUTES, HOURS, DAYS |
|
|
The amount of time expressed with the unit |
|
type |
integer |
|
additionalProperties |
False |
|
ESCALATE
type |
object |
|
properties |
||
|
type |
string |
enum |
ESCALATE |
|
default |
ESCALATE |
|
|
The period of time after which alarms with this expire. This duration must be expressed as _value_ and _unit_. |
|
|
The id of the new severity to use on expiration for the ESCALATE type. The alarm severity will change to the given severity on expiration. |
|
type |
string |
|
|
The state of the alarm can be used to limit the expiration. ACKNOWLEDGED to only check on acknowledged alarm, UNACKNOWLEDGED or ALL. |
|
type |
string |
|
enum |
ALL, ACKNOWLEDGED, UNACKNOWLEDGED |
|
additionalProperties |
False |
|