owner-criteria.ip-rct

IP-RCT criteria owner

type

object

properties

  • alarmData

The alarm data represented by this value. Depending on the SPT protocol used for alarm transmission, some fields may not be available (empty). When the CRITERIA alarm data is used, criteria’s alarm and restore expressions are used to generate the value content. If the alarm matches the criteria’s alarm expression the value content is set to true, and if the alarm matches the criteria’s restore expression the value content is set to false.

For example, a STATE must be linked to a value of type BOOLEAN, INTEGER, DECIMAL or TEXT.

Since there is a lot of options possible for the alarm data please refer to this documentation ↗️ for a complete documentation about alarmData.

type

string

enum

CRITERIA, MAINTENANCE, SPT_NAME, SPT_DESCRIPTION, SPT_CUSTOMER_COMPANY, SPT_CUSTOMER_CONTACT, SPT_CUSTOMER_ADDRESS, SPT_CUSTOMER_PIN, SPT_CUSTOMER_PHONE, SPT_CUSTOMER_EMAIL, BUILDING, LOCATION, ROOM, VERIFICATION, INFO, OCCURRENCE, SITE, LONGITUDE, LATITUDE, ALTITUDE, STATE, ACCOUNT, ACCOUNT_INFO, TYPE, TYPE_INFO, ADDRESS, DATE, DATE_INFO, TIME, TIME_INFO, USER, USER_INFO, AREA, AREA_INFO, PERIPHERAL, PERIPHERAL_INFO, AUTOMATED, AUTOMATED_INFO, PHONE, PHONE_INFO, LEVEL, LEVEL_INFO, VALUE, VALUE_INFO, PATH, PATH_INFO, GROUP, GROUP_INFO, SUBSUBSCRIBER, SUBSUBSCRIBER_INFO

  • disableEventOrdering

When handling event, we store the last event timestamp. Should an event have a date smaller than current event, we discard it by default. To disable disable event ordering, use true value.

Default value is [false]

type

boolean

default

False

  • isTemplateGeneratedByOspComposer

Name of the playbook that generated this file. If present, the file is managed by the Composer and may be overwritten on regeneration. Used for selective clean. Do not edit or set manually.

type

string

  • linkedCriteria

The IP-RCT criteria criteria.ip-rct ↗️ that this device will use to communicate.

For example servers.ip-rct.device.ip-rct could be a path of the IP-RCT device.

type

string

  • templateId

The id of the template to use for this file

type

string

  • templateVariables

The variables and their values to be replaced from the template

type

object

additionalProperties

  • variablesFiles

The variables files to use to replace the variables. The first file of the list will take precedence over the following one. Template variables take precedence over the contents of the files.

type

array

items

type

string

additionalProperties

False