owner.network-monitoring

NetworkMonitoring owner

type

object

properties

  • address

The address (IPv4, IPv6 or hostname) of the monitored service

type

string

  • failThreshold

The number of polling failures before reporting error

Default value is [3]

type

integer

default

3

  • isTemplateGeneratedByOspComposer

Name of the playbook that generated this file. If present, the file is managed by the Composer and may be overwritten on regeneration. Used for selective clean. Do not edit or set manually.

type

string

  • moduleId

The id of the owner module of the item

type

string

  • pollPeriod

The duration between polling requests

Default value is [{“unit”:”MINUTES”,”value”:5}]

default

unit

MINUTES

value

5

DurationConfigurationEntity

  • protocol

The protocol used for monitoring

type

string

enum

ICMP

  • templateId

The id of the template to use for this file

type

string

  • templateVariables

The variables and their values to be replaced from the template

type

object

additionalProperties

  • timeout

The duration after which the polling requests time out

Default value is [{“unit”:”SECONDS”,”value”:10}]

default

unit

SECONDS

value

10

DurationConfigurationEntity

  • variablesFiles

The variables files to use to replace the variables. The first file of the list will take precedence over the following one. Template variables take precedence over the contents of the files.

type

array

items

type

string

additionalProperties

False

DurationConfigurationEntity

type

object

properties

  • unit

The unit of time expressed

type

string

enum

NANOSECONDS, MICROSECONDS, MILLISECONDS, SECONDS, MINUTES, HOURS, DAYS

  • value

The amount of time expressed with the unit

type

integer

additionalProperties

False