OPC-DA
Capabilities
Capability |
Support |
Comment |
|---|---|---|
OPC-UA protocol |
See OPC-UA |
|
Connection state monitoring of OPC-DA server |
||
Reading value by subscription from OPC-DA server |
||
Writing value from OPC-DA server |
See Writing values |
Supported types
Concept
Overview
OnSphere allows you to easily read (Reading values using subscription) and write (Writing values) data on a OPC-DA server. The status of connection between OnSphere and the OPC-DA server is also monitored.
Here are the possible connection parameters for an OPC DA server :
OnSphere Type transformation
Opc Da Type |
OnSphere Type |
|---|---|
BSTR |
TEXT |
BOOL |
BOOLEAN |
I1 |
TEXT |
I2 |
NUMBER |
I4 |
NUMBER |
UI1 |
NUMBER |
UI2 |
NUMBER |
UI4 |
NUMBER |
R4 |
DECIMAL |
R8 |
DECIMAL |
Note
If a type is not in the above table it is not officially supported but it does not mean it won’t work.
Connect
Here are the possible connection parameters for an OPC DA Server :
Field |
Description |
Support |
Usage |
|---|---|---|---|
classId |
The class Id of the OPC DA Server |
Tells which application to connect to on the Windows machine |
|
progId |
The programme Id of the OPC DA Server |
Tells which application to connect to on the Windows machine |
|
domain |
The domain of the Windows machine you are trying to reach |
||
passwordProvider |
The OPC DA Server password |
||
host |
The host of the OPC DA Server |
Note
It is recommended to use classId if possible. If the classId and the progId are provided the classId has priority.
Server monitoring connection state
Concept
The connection state between the OPC-DA server and a server can be read as a BOOLEAN value from the OPC-DA device in the OnSphere hierarchy (i.e. root.opc_da.server1 for example). If the connection is not working the state will be set to false.
Usage
A typical use case would be to monitor the status of an OPC-DA server
Reading values using subscription
Concept
OnSphere will read a specific itemId once the server is reachable (once the connection state value is set to true). Once it was read for the first time it will then subscribe to it and notice OnSphere when a change occurs. The module allows you to read an itemId by defining a owner.
When reading a value please refer to the correct OnSphere type following this table.
Usage
A typical use case would be to monitor a temperature of a boiler.
Writing values
Concept
The module allows you to write on an OPC-DA device on demand. OnSphere allows OPC-DA writing through callbacks: define your output and simply reference it in a callback.
When writing a value please refer to the correct OnSphere type following this table.
Usage
A typical use case would be to control the speed of a motor.